CVE-2021-22805
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause...
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.1
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
- Record
CVE-2021-22805- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H - CVSS 2.0
- 5.0 Medium
AV:N/AC:L/Au:N/C:N/I:P/A:N - Weakness
- CWE-306
- Updated
- 2026-11-02
CVE List No score
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
- Record
CVE-2021-22805- Weakness
- CWE-306
- Updated
- 2026-11-02
EUVDEUVD-2021-9940 No score
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
- Record
EUVD-2021-9940- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-px95-pcrx-64c4 No score
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause...
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
- Record
GHSA-px95-pcrx-64c4- Weakness
- CWE-306
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2021-22805 is a critical vulnerability (CVSS 9.1) in Schneider-electric Interactive Graphical Scada System Data Collector, published February 11, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.85%, the 58th percentile. No source names a fixed version.