Every CVE Search/ Get API key

CVE-2021-22824

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in...

7.5 High

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

14.2%Up 13.4 points since Feb 13, 2022
90%50%10%1%

What each source reports

NVD Score used 7.5

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)

Record
CVE-2021-22824
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:N/I:N/A:P
Weakness
CWE-120
Updated
2026-11-02
CVE List No score

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)

Record
CVE-2021-22824
Weakness
CWE-120
Updated
2026-11-02
EUVDEUVD-2021-9959 No score

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)

Record
EUVD-2021-9959
Updated
2026-11-03
GitHub AdvisoriesGHSA-rcg3-66pc-3vp9 No score

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in...

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)

Record
GHSA-rcg3-66pc-3vp9
Weakness
CWE-120
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-22824 is a high vulnerability (CVSS 7.5) in Schneider-electric Interactive Graphical Scada System Data Collector, published February 11, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 14.2%, the 96th percentile. No source names a fixed version.

References

MoveEnter Open