CVE-2021-26638
Xi Smarthome wallpad authentication bypass vulnerability
Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
7.3
Xi Smarthome wallpad authentication bypass vulnerability
Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.
- Record
CVE-2021-26638- CVSS 3.1
- 7.3 High
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N - Weakness
- CWE-287
- Updated
- 2026-11-02
EUVDEUVD-2021-13432
7.3
Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.
- Record
EUVD-2021-13432- CVSS 3.1
- 7.3 High
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-82jv-68vh-8wp7
9.8
Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause...
Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.
- Record
GHSA-82jv-68vh-8wp7- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-287
- Updated
- 2026-11-02
NVD
7.3
Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.
- Record
CVE-2021-26638- CVSS 3.1
- 7.3 High
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N - CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 10.0 High
AV:N/AC:L/Au:N/C:C/I:C/A:C - Weakness
- CWE-287
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2021-26638 is a high vulnerability (CVSS 7.3) in Xi S&d Inc. S&d Smarthome (smartcare), published June 22, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 3.79%, the 90th percentile. No source names a fixed version.