Every CVE Search/ Get API key

CVE-2021-26638

Xi Smarthome wallpad authentication bypass vulnerability

7.3 High

Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
None

Exploit likelihood

3.79%Up 2.7 points since Jun 23, 2022
90%50%10%1%

What each source reports

CVE List Score used 7.3

Xi Smarthome wallpad authentication bypass vulnerability

Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.

Record
CVE-2021-26638
CVSS 3.1
7.3 HighCVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Weakness
CWE-287
Updated
2026-11-02
EUVDEUVD-2021-13432 7.3

Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.

Record
EUVD-2021-13432
CVSS 3.1
7.3 HighCVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Updated
2026-11-03
GitHub AdvisoriesGHSA-82jv-68vh-8wp7 9.8

Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause...

Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.

Record
GHSA-82jv-68vh-8wp7
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-287
Updated
2026-11-02
NVD 7.3

Improper Authentication vulnerability in S&D smarthome(smartcare) application can cause authentication bypass and information exposure. Remote attackers can use this vulerability to take control of the home environment including indoor control.

Record
CVE-2021-26638
CVSS 3.1
7.3 HighCVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
10.0 HighAV:N/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-287
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-26638 is a high vulnerability (CVSS 7.3) in Xi S&d Inc. S&d Smarthome (smartcare), published June 22, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 3.79%, the 90th percentile. No source names a fixed version.

References

MoveEnter Open