Every CVE Search/ Get API key

CVE-2021-27113

An issue was discovered in D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used...

9.8 Critical

An issue was discovered in D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/addRouting route. This could lead to Command Injection via Shell Metacharacters.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

3.46%Up 2.8 points since Apr 15, 2021
90%50%10%1%

What each source reports

NVD Score used 9.8

An issue was discovered in D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/addRouting route. This could lead to Command Injection via Shell Metacharacters.

Record
CVE-2021-27113
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
10.0 HighAV:N/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-78
Updated
2026-11-02
CVE List No score

An issue was discovered in D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/addRouting route. This could lead to Command Injection via Shell Metacharacters.

Record
CVE-2021-27113
Updated
2026-11-02
EUVDEUVD-2021-13883 No score

An issue was discovered in D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/addRouting route. This could lead to Command Injection via Shell Metacharacters.

Record
EUVD-2021-13883
Updated
2026-11-03
GitHub AdvisoriesGHSA-26w9-85c6-ccr8 No score

An issue was discovered in D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used...

An issue was discovered in D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/addRouting route. This could lead to Command Injection via Shell Metacharacters.

Record
GHSA-26w9-85c6-ccr8
Weakness
CWE-78
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-27113 is a critical vulnerability (CVSS 9.8) in Dlink Dir-816 Firmware, published April 14, 2021. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 3.46%, the 89th percentile. No source names a fixed version.

References

MoveEnter Open