Every CVE Search/ Get API key

CVE-2021-30127

TerraMaster F2-210 devices through 2021-04-03 use UPnP to make the admin web server accessible...

7.3 High

TerraMaster F2-210 devices through 2021-04-03 use UPnP to make the admin web server accessible over the Internet on TCP port 8181, which is arguably inconsistent with the "It is only available on the local network" documentation. NOTE: manually editing /etc/upnp.json provides a partial but undocumented workaround.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
Low
Availability
Low

Exploit likelihood

0.88%Up 0.2 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.3

TerraMaster F2-210 devices through 2021-04-03 use UPnP to make the admin web server accessible over the Internet on TCP port 8181, which is arguably inconsistent with the "It is only available on the local network" documentation. NOTE: manually editing /etc/upnp.json provides a partial but undocumented workaround.

Record
CVE-2021-30127
CVSS 3.1
7.3 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
CVSS 2.0
7.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P
Updated
2026-11-02
CVE List No score

TerraMaster F2-210 devices through 2021-04-03 use UPnP to make the admin web server accessible over the Internet on TCP port 8181, which is arguably inconsistent with the "It is only available on the local network" documentation. NOTE: manually editing /etc/upnp.json provides a partial but undocumented workaround.

Record
CVE-2021-30127
Updated
2026-11-02
EUVDEUVD-2021-17067 No score

TerraMaster F2-210 devices through 2021-04-03 use UPnP to make the admin web server accessible over the Internet on TCP port 8181, which is arguably inconsistent with the "It is only available on the local network" documentation. NOTE: manually editing /etc/upnp.json provides a partial but undocumented workaround.

Record
EUVD-2021-17067
Updated
2026-11-03
GitHub AdvisoriesGHSA-mr2c-pv2q-gwvr 7.3

TerraMaster F2-210 devices through 2021-04-03 use UPnP to make the admin web server accessible...

TerraMaster F2-210 devices through 2021-04-03 use UPnP to make the admin web server accessible over the Internet on TCP port 8181, which is arguably inconsistent with the "It is only available on the local network" documentation. NOTE: manually editing /etc/upnp.json provides a partial but undocumented workaround.

Record
GHSA-mr2c-pv2q-gwvr
CVSS 3.1
7.3 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Weakness
CWE-863
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-30127 is a high vulnerability (CVSS 7.3) in Terra-master F2-210 Firmware, published April 3, 2021. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.88%, the 59th percentile. No source names a fixed version.

References

MoveEnter Open