Every CVE Search/ Get API key

CVE-2021-31342

A vulnerability has been identified in Solid Edge SE2020 (All Versions < 2020MP14), Solid Edge...

8.8 High

The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
Required

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

2.50%Up 1.8 points since Jun 9, 2021
90%50%10%1%

What each source reports

NVD Score used 8.8

The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Record
CVE-2021-31342
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS 2.0
6.8 MediumAV:N/AC:M/Au:N/C:P/I:P/A:P
Weakness
CWE-787
Updated
2026-11-02
CVE List No score

The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Record
CVE-2021-31342
Weakness
CWE-787
Updated
2026-11-02
EUVDEUVD-2021-18252 No score

The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Record
EUVD-2021-18252
Updated
2026-11-03
GitHub AdvisoriesGHSA-xphh-j59m-3cvp No score

A vulnerability has been identified in Solid Edge SE2020 (All Versions < 2020MP14), Solid Edge...

A vulnerability has been identified in Solid Edge SE2020 (All Versions < 2020MP14), Solid Edge SE2021 (All Versions < SE2021MP5). The ugeom2d.dll library lacks proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12993)

Record
GHSA-xphh-j59m-3cvp
Weakness
CWE-787
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-31342 is a high vulnerability (CVSS 8.8) in Siemens Solid Edge Se2020 Firmware, published June 8, 2021. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.50%, the 84th percentile. No source names a fixed version.