Every CVE Search/ Get API key

CVE-2021-36707

In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary,...

9.8 Critical

In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

2.62%Up 2.2 points since Aug 7, 2021
90%50%10%1%

What each source reports

NVD Score used 9.8

In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.

Record
CVE-2021-36707
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
7.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P
Weakness
CWE-77
Updated
2026-11-02
CVE List No score

In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.

Record
CVE-2021-36707
Updated
2026-11-02
EUVDEUVD-2021-23302 No score

In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.

Record
EUVD-2021-23302
Updated
2026-11-03
GitHub AdvisoriesGHSA-f8hv-38c8-7mr9 No score

In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary,...

In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.

Record
GHSA-f8hv-38c8-7mr9
Weakness
CWE-77
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-36707 is a critical vulnerability (CVSS 9.8) in Prolink Prc2402m Firmware, published August 6, 2021. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.62%, the 85th percentile. No source names a fixed version.

References

MoveEnter Open