Every CVE Search/ Get API key

CVE-2021-46452

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection...

9.8 Critical

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via the tomography_ping_address, tomography_ping_number, tomography_ping_size, tomography_ping_timeout, and tomography_ping_ttl parameters.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

3.75%Up 2.7 points since Feb 4, 2022
90%50%10%1%

What each source reports

NVD Score used 9.8

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via the tomography_ping_address, tomography_ping_number, tomography_ping_size, tomography_ping_timeout, and tomography_ping_ttl parameters.

Record
CVE-2021-46452
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
7.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P
Weakness
CWE-77
Updated
2026-11-02
CVE List No score

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via the tomography_ping_address, tomography_ping_number, tomography_ping_size, tomography_ping_timeout, and tomography_ping_ttl parameters.

Record
CVE-2021-46452
Updated
2026-11-02
EUVDEUVD-2021-33128 No score

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via the tomography_ping_address, tomography_ping_number, tomography_ping_size, tomography_ping_timeout, and tomography_ping_ttl parameters.

Record
EUVD-2021-33128
Updated
2026-11-03
GitHub AdvisoriesGHSA-ggcw-6ww3-6675 9.8

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection...

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via the tomography_ping_address, tomography_ping_number, tomography_ping_size, tomography_ping_timeout, and tomography_ping_ttl parameters.

Record
GHSA-ggcw-6ww3-6675
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-77
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-46452 is a critical vulnerability (CVSS 9.8) in Dlink Dir-823 Pro Firmware, published February 4, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 3.75%, the 89th percentile. No source names a fixed version.

References

MoveEnter Open