Every CVE Search/ Get API key

CVE-2022-23448

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1...

7.8 High

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.25%Down 2.3 points since Apr 13, 2022
90%50%10%1%

What each source reports

NVD Score used 7.8

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.

Record
CVE-2022-23448
CVSS 3.1
7.8 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
7.2 HighAV:L/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-732
Updated
2026-11-02
CVE List No score

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.

Record
CVE-2022-23448
Weakness
CWE-732
Updated
2026-11-02
EUVDEUVD-2022-28523 No score

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.

Record
EUVD-2022-28523
Updated
2026-11-03
GitHub AdvisoriesGHSA-5hqf-83pf-c8gv 7.8

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1...

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.

Record
GHSA-5hqf-83pf-c8gv
CVSS 3.1
7.8 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-732
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2022-23448 is a high vulnerability (CVSS 7.8) in Siemens Simatic Energy Manager Basic, published April 12, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.25%, the 16th percentile. No source names a fixed version.

References

MoveEnter Open