CVE-2022-23448
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1...
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
7.8
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.
- Record
CVE-2022-23448- CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 7.2 High
AV:L/AC:L/Au:N/C:C/I:C/A:C - Weakness
- CWE-732
- Updated
- 2026-11-02
CVE List No score
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.
- Record
CVE-2022-23448- Weakness
- CWE-732
- Updated
- 2026-11-02
EUVDEUVD-2022-28523 No score
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.
- Record
EUVD-2022-28523- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-5hqf-83pf-c8gv
7.8
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1...
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.
- Record
GHSA-5hqf-83pf-c8gv- CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-732
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2022-23448 is a high vulnerability (CVSS 7.8) in Siemens Simatic Energy Manager Basic, published April 12, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.25%, the 16th percentile. No source names a fixed version.