Every CVE Search/ Get API key

CVE-2022-23449

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1...

7.3 High

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
Low
User interaction
Required

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.33%Down 2.2 points since Apr 13, 2022
90%50%10%1%

What each source reports

NVD Score used 7.3

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.

Record
CVE-2022-23449
CVSS 3.1
7.3 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
CVSS 2.0
6.9 MediumAV:L/AC:M/Au:N/C:C/I:C/A:C
Weakness
CWE-427
Updated
2026-11-02
CVE List No score

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.

Record
CVE-2022-23449
Weakness
CWE-427
Updated
2026-11-02
EUVDEUVD-2022-28524 No score

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.

Record
EUVD-2022-28524
Updated
2026-11-03
GitHub AdvisoriesGHSA-fc86-6r8m-346f 7.3

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1...

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.

Record
GHSA-fc86-6r8m-346f
CVSS 3.1
7.3 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-427
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2022-23449 is a high vulnerability (CVSS 7.3) in Siemens Simatic Energy Manager Basic, published April 12, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.33%, the 25th percentile. No source names a fixed version.

References

MoveEnter Open