CVE-2022-23449
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1...
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- Required
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
7.3
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
- Record
CVE-2022-23449- CVSS 3.1
- 7.3 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H - CVSS 2.0
- 6.9 Medium
AV:L/AC:M/Au:N/C:C/I:C/A:C - Weakness
- CWE-427
- Updated
- 2026-11-02
CVE List No score
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
- Record
CVE-2022-23449- Weakness
- CWE-427
- Updated
- 2026-11-02
EUVDEUVD-2022-28524 No score
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
- Record
EUVD-2022-28524- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-fc86-6r8m-346f
7.3
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1...
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
- Record
GHSA-fc86-6r8m-346f- CVSS 3.1
- 7.3 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H - Weakness
- CWE-427
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2022-23449 is a high vulnerability (CVSS 7.3) in Siemens Simatic Energy Manager Basic, published April 12, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.33%, the 25th percentile. No source names a fixed version.