CVE-2022-24285
Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability....
Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
7.8
Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.
- Record
CVE-2022-24285- CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 7.2 High
AV:L/AC:L/Au:N/C:C/I:C/A:C - Weakness
- CWE-287
- Updated
- 2026-11-02
CVE List No score
Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.
- Record
CVE-2022-24285- Updated
- 2026-11-02
EUVDEUVD-2022-29189 No score
Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.
- Record
EUVD-2022-29189- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-6x9r-4356-fx8g
7.8
Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability....
Acer Care Center 4.00.30xx before 4.00.3042 contains a local privilege escalation vulnerability. The user process communicates with a service of system authority called ACCsvc through a named pipe. In this case, the Named Pipe is also given Read and Write rights to the general user. In addition, the service program does not verify the user when communicating. A thread may exist with a specific command. When the path of the program to be executed is sent, there is a local privilege escalation in which the service program executes the path with system privileges.
- Record
GHSA-6x9r-4356-fx8g- CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-287
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2022-24285 is a high vulnerability (CVSS 7.8) in Acer Care Center, published March 8, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.22%, the 13th percentile. No source names a fixed version.