Every CVE Search/ Get API key

CVE-2022-24322

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability...

5.3 Medium

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
High
Privileges needed
None
User interaction
Required

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

0.64%Down 0.2 points since Mar 10, 2022
90%50%10%1%

What each source reports

CVE List Score used 5.3

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)

Record
CVE-2022-24322
CVSS 3.1
5.3 MediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H
Weakness
CWE-119
Updated
2026-11-02
EUVDEUVD-2022-29220 5.3

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)

Record
EUVD-2022-29220
CVSS 3.1
5.3 MediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-wwjr-j4cg-w355 5.9

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability...

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)

Record
GHSA-wwjr-j4cg-w355
CVSS 3.1
5.9 MediumCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
Weakness
CWE-119
Updated
2026-11-02
NVD 5.3

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)

Record
CVE-2022-24322
CVSS 3.1
5.3 MediumCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H
CVSS 3.1
5.9 MediumCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
CVSS 2.0
4.3 MediumAV:N/AC:M/Au:N/C:N/I:P/A:N
Weakness
CWE-119
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2022-24322 is a medium vulnerability (CVSS 5.3) in Schneider Electric Ecostruxure Control Expert, published March 9, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.64%, the 51st percentile. No source names a fixed version.

References

MoveEnter Open