CVE-2022-24323
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could...
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- High
- Privileges needed
- None
- User interaction
- Required
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
5.3
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)
- Record
CVE-2022-24323- CVSS 3.1
- 5.3 Medium
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H - Weakness
- CWE-754
- Updated
- 2026-11-02
EUVDEUVD-2022-29221
5.3
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)
- Record
EUVD-2022-29221- CVSS 3.1
- 5.3 Medium
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-wxpm-2rxr-g39h
5.9
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could...
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)
- Record
GHSA-wxpm-2rxr-g39h- CVSS 3.1
- 5.9 Medium
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N - Weakness
- CWE-754
- Updated
- 2026-11-02
NVD
5.3
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)
- Record
CVE-2022-24323- CVSS 3.1
- 5.3 Medium
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H - CVSS 3.1
- 5.9 Medium
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N - CVSS 2.0
- 4.3 Medium
AV:N/AC:M/Au:N/C:N/I:P/A:N - Weakness
- CWE-754
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2022-24323 is a medium vulnerability (CVSS 5.3) in Schneider Electric Ecostruxure Control Expert, published March 9, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.86%, the 58th percentile. No source names a fixed version.