CVE-2022-25106
D-Link DIR-859 v1.05 was discovered to contain a stack-based buffer overflow via the function...
D-Link DIR-859 v1.05 was discovered to contain a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted payload.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- None
- User interaction
- Required
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
5.5
D-Link DIR-859 v1.05 was discovered to contain a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted payload.
- Record
CVE-2022-25106- CVSS 3.1
- 5.5 Medium
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H - CVSS 2.0
- 7.1 High
AV:N/AC:M/Au:N/C:N/I:N/A:C - Weakness
- CWE-787
- Updated
- 2026-11-02
CVE List No score
D-Link DIR-859 v1.05 was discovered to contain a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted payload.
- Record
CVE-2022-25106- Updated
- 2026-11-02
EUVDEUVD-2022-29849 No score
D-Link DIR-859 v1.05 was discovered to contain a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted payload.
- Record
EUVD-2022-29849- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-wjq5-hxjh-57xx
5.5
D-Link DIR-859 v1.05 was discovered to contain a stack-based buffer overflow via the function...
D-Link DIR-859 v1.05 was discovered to contain a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted payload.
- Record
GHSA-wjq5-hxjh-57xx- CVSS 3.1
- 5.5 Medium
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H - Weakness
- CWE-787
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2022-25106 is a medium vulnerability (CVSS 5.5) in Dlink Dir-859 A3 Firmware, published March 4, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 8.59%, the 95th percentile. No source names a fixed version.