Improper Access Control Vulnerability in ELI Electrocardiograph Devices

7.7 High

An improper access control vulnerability may allow privilege escalation.This issue affects: 

  • ELI 380 Resting Electrocardiograph:

Versions 2.6.0 and prior; 

  • ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:

Versions 2.3.1 and prior; 

  • ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior; 
  • ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph:

Versions 2.2.0 and prior.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
High
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
Low
Availability
High

Exploit likelihood

0.29%Up 0.2 points since Feb 8, 2025
90%50%10%1%

What each source reports

CVE List Score used7.7

Improper Access Control Vulnerability in ELI Electrocardiograph Devices

An improper access control vulnerability may allow privilege escalation.This issue affects: 

  • ELI 380 Resting Electrocardiograph:

Versions 2.6.0 and prior; 

  • ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:

Versions 2.3.1 and prior; 

  • ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior; 
  • ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph:

Versions 2.2.0 and prior.

Record
CVE-2022-26389
CVSS 3.1
7.7 HighCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:H
Weakness
CWE-284
Updated
2026-11-02
EUVDEUVD-2022-309487.7

An improper access control vulnerability may allow privilege escalation.This issue affects: 

  • ELI 380 Resting Electrocardiograph:

Versions 2.6.0 and prior; 

  • ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:

Versions 2.3.1 and prior; 

  • ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior; 
  • ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph:

Versions 2.2.0 and prior.

Record
EUVD-2022-30948
CVSS 3.1
7.7 HighCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-9qm3-wmwv-68w57.7

An improper access control vulnerability may allow privilege escalation.This issue affects:  *...

An improper access control vulnerability may allow privilege escalation.This issue affects: 

  • ELI 380 Resting Electrocardiograph:

Versions 2.6.0 and prior; 

  • ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:

Versions 2.3.1 and prior; 

  • ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior; 
  • ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph:

Versions 2.2.0 and prior.

Record
GHSA-9qm3-wmwv-68w5
CVSS 3.1
7.7 HighCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:H
Weakness
CWE-284
Updated
2026-11-02
NVD7.7

An improper access control vulnerability may allow privilege escalation.This issue affects: 

  • ELI 380 Resting Electrocardiograph:

Versions 2.6.0 and prior; 

  • ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:

Versions 2.3.1 and prior; 

  • ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior; 
  • ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph:

Versions 2.2.0 and prior.

Record
CVE-2022-26389
CVSS 3.1
7.7 HighCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:H
Weakness
CWE-284
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2022-26389 is a high vulnerability (CVSS 7.7) in Welch Allyn Eli 150c/bur 150c/mlbur 150c Resting Electrocardiograph, published February 7, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.29%, the 21st percentile. No source names a fixed version.

References

MoveEnter Open