CVE-2022-28377
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices,...
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU).
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
NVD Score used
7.5
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU).
- Record
CVE-2022-28377- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-521
- Updated
- 2026-11-02
CVE List No score
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU).
- Record
CVE-2022-28377- Updated
- 2026-11-02
EUVDEUVD-2022-32823 No score
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU).
- Record
EUVD-2022-32823- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-6hxh-v9xw-6688
7.5
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices,...
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU).
- Record
GHSA-6hxh-v9xw-6688- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-521
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2022-28377 is a high vulnerability (CVSS 7.5) in Verizon Lvskihp Indoorunit Firmware, published July 14, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.97%, the 61st percentile. No source names a fixed version.