CVE-2022-28618
A command injection security vulnerability has been identified in HPE Nimble Storage Hybrid Flash...
A command injection security vulnerability has been identified in HPE Nimble Storage Hybrid Flash Arrays, HPE Nimble Storage All Flash Arrays and HPE Nimble Storage Secondary Flash Arrays that could allow an attacker to execute arbitrary commands on a Nimble appliance. HPE has made the following software updates to resolve the vulnerability in HPE Nimble Storage: 5.0.10.100 or later, 5.2.1.0 or later, 6.0.0.100 or later.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
A command injection security vulnerability has been identified in HPE Nimble Storage Hybrid Flash Arrays, HPE Nimble Storage All Flash Arrays and HPE Nimble Storage Secondary Flash Arrays that could allow an attacker to execute arbitrary commands on a Nimble appliance. HPE has made the following software updates to resolve the vulnerability in HPE Nimble Storage: 5.0.10.100 or later, 5.2.1.0 or later, 6.0.0.100 or later.
- Record
CVE-2022-28618- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 7.5 High
AV:N/AC:L/Au:N/C:P/I:P/A:P - Weakness
- CWE-77
- Updated
- 2026-11-02
CVE List No score
A command injection security vulnerability has been identified in HPE Nimble Storage Hybrid Flash Arrays, HPE Nimble Storage All Flash Arrays and HPE Nimble Storage Secondary Flash Arrays that could allow an attacker to execute arbitrary commands on a Nimble appliance. HPE has made the following software updates to resolve the vulnerability in HPE Nimble Storage: 5.0.10.100 or later, 5.2.1.0 or later, 6.0.0.100 or later.
- Record
CVE-2022-28618- Updated
- 2026-11-02
EUVDEUVD-2022-33060 No score
A command injection security vulnerability has been identified in HPE Nimble Storage Hybrid Flash Arrays, HPE Nimble Storage All Flash Arrays and HPE Nimble Storage Secondary Flash Arrays that could allow an attacker to execute arbitrary commands on a Nimble appliance. HPE has made the following software updates to resolve the vulnerability in HPE Nimble Storage: 5.0.10.100 or later, 5.2.1.0 or later, 6.0.0.100 or later.
- Record
EUVD-2022-33060- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-xvr4-pc95-4727
9.8
A command injection security vulnerability has been identified in HPE Nimble Storage Hybrid Flash...
A command injection security vulnerability has been identified in HPE Nimble Storage Hybrid Flash Arrays, HPE Nimble Storage All Flash Arrays and HPE Nimble Storage Secondary Flash Arrays that could allow an attacker to execute arbitrary commands on a Nimble appliance. HPE has made the following software updates to resolve the vulnerability in HPE Nimble Storage: 5.0.10.100 or later, 5.2.1.0 or later, 6.0.0.100 or later.
- Record
GHSA-xvr4-pc95-4727- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-77
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2022-28618 is a critical vulnerability (CVSS 9.8) in Hpe Nimbleos, published May 20, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.82%, the 78th percentile. No source names a fixed version.