Every CVE Search/ Get API key

CVE-2022-29898

Remote Code Execution in all versions of various RAD-ISM-900-EN-* devices by PHOENIX CONTACT

9.1 Critical

On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.65%Down 0.7 points since May 12, 2022
90%50%10%1%

What each source reports

CVE List Score used 9.1

Remote Code Execution in all versions of various RAD-ISM-900-EN-* devices by PHOENIX CONTACT

On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.

Record
CVE-2022-29898
CVSS 3.1
9.1 CriticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-354
Updated
2026-11-02
EUVDEUVD-2022-34208 9.1

On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.

Record
EUVD-2022-34208
CVSS 3.1
9.1 CriticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-gg9m-7hf2-hmp9 9.1

On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration...

On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.

Record
GHSA-gg9m-7hf2-hmp9
CVSS 3.1
9.1 CriticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-354
Updated
2026-11-02
NVD 9.1

On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.

Record
CVE-2022-29898
CVSS 3.1
9.1 CriticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
CVSS 2.0
9.0 HighAV:N/AC:L/Au:S/C:C/I:C/A:C
Weakness
CWE-354
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2022-29898 is a critical vulnerability (CVSS 9.1) in Phoenix Contact Rad-ism-900-en-bd, published May 11, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.65%, the 51st percentile. No source names a fixed version.

References

MoveEnter Open