Every CVE Search/ Get API key

CVE-2022-3027

Contec Health CMS8000

5.7 Medium

The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
None
User interaction
Required

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

0.32%Down 0.6 points since Sep 14, 2022
90%50%10%1%

What each source reports

CVE List Score used 5.7

Contec Health CMS8000

The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information.

Record
CVE-2022-3027
CVSS 3.1
5.7 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
Weakness
CWE-284
Updated
2026-11-02
EUVDEUVD-2022-42461 5.7

The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information.

Record
EUVD-2022-42461
CVSS 3.1
5.7 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-q7x7-x9qf-5p7c 5.7

The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access...

The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information.

Record
GHSA-q7x7-x9qf-5p7c
CVSS 3.1
5.7 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N
Updated
2026-11-02
NVD 5.7

The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information.

Record
CVE-2022-3027
CVSS 3.1
5.7 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
CVSS 3.1
5.7 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N
Weakness
CWE-284
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2022-3027 is a medium vulnerability (CVSS 5.7) in Contec Health Cms8000 Contec Icu Ccu Vital Signs Patient Monitor, published September 13, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.32%, the 25th percentile. No source names a fixed version.

References

MoveEnter Open