CVE-2022-31079
KubeEdge Cloud Stream and Edge Stream DoS from large stream message
KubeEdge is an open source system for extending native containerized application orchestration capabilities to hosts at Edge. Prior to versions 1.11.1, 1.10.2, and 1.9.4, the Cloud Stream server and the Edge Stream server reads the entire message into memory without imposing a limit on the size of this message. An attacker can exploit this by sending a large message to exhaust memory and cause a DoS. The Cloud Stream server and the Edge Stream server are under DoS attack in this case. The consequence of the exhaustion is that the CloudCore and EdgeCore will be in a denial of service. Only an authenticated user can cause this issue. It will be affected only when users enable cloudStream module in the config file cloudcore.yaml and enable edgeStream module in the config file edgecore.yaml. This bug has been fixed in Kubeedge 1.11.1, 1.10.2, and 1.9.4. As a workaround, disable cloudStream module in the config file cloudcore.yaml and disable edgeStream module in the config file edgecore.yaml.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- High
- Privileges needed
- High
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
4.4
KubeEdge Cloud Stream and Edge Stream DoS from large stream message
KubeEdge is an open source system for extending native containerized application orchestration capabilities to hosts at Edge. Prior to versions 1.11.1, 1.10.2, and 1.9.4, the Cloud Stream server and the Edge Stream server reads the entire message into memory without imposing a limit on the size of this message. An attacker can exploit this by sending a large message to exhaust memory and cause a DoS. The Cloud Stream server and the Edge Stream server are under DoS attack in this case. The consequence of the exhaustion is that the CloudCore and EdgeCore will be in a denial of service. Only an authenticated user can cause this issue. It will be affected only when users enable cloudStream module in the config file cloudcore.yaml and enable edgeStream module in the config file edgecore.yaml. This bug has been fixed in Kubeedge 1.11.1, 1.10.2, and 1.9.4. As a workaround, disable cloudStream module in the config file cloudcore.yaml and disable edgeStream module in the config file edgecore.yaml.
- Record
CVE-2022-31079- CVSS 3.1
- 4.4 Medium
CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-400
- Updated
- 2026-11-02
EUVDEUVD-2022-6440
4.4
KubeEdge is an open source system for extending native containerized application orchestration capabilities to hosts at Edge. Prior to versions 1.11.1, 1.10.2, and 1.9.4, the Cloud Stream server and the Edge Stream server reads the entire message into memory without imposing a limit on the size of this message. An attacker can exploit this by sending a large message to exhaust memory and cause a DoS. The Cloud Stream server and the Edge Stream server are under DoS attack in this case. The consequence of the exhaustion is that the CloudCore and EdgeCore will be in a denial of service. Only an authenticated user can cause this issue. It will be affected only when users enable cloudStream module in the config file cloudcore.yaml and enable edgeStream module in the config file edgecore.yaml. This bug has been fixed in Kubeedge 1.11.1, 1.10.2, and 1.9.4. As a workaround, disable cloudStream module in the config file cloudcore.yaml and disable edgeStream module in the config file edgecore.yaml.
- Record
EUVD-2022-6440- CVSS 3.1
- 4.4 Medium
CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-wrcr-x4qj-j543
4.4
KubeEdge Cloud Stream and Edge Stream DoS from large stream message
Impact
The Cloud Stream server and the Edge Stream server reads the entire message into memory without imposing a limit on the size of this message. An attacker can exploit this by sending a large message to exhaust memory and cause a DoS. The Cloud Stream server and the Edge Stream server are under DoS attack in this case. The consequence of the exhaustion is that the CloudCore and EdgeCore will be in a denial of service. Only an authenticated user can cause this issue. It will be affected only when users enable cloudStream module in the config file cloudcore.yaml and enable edgeStream module in the config file edgecore.yaml as below. cloudcore.yaml:
modules:
...
cloudStream:
enable: true
edgecore.yaml:
modules:
...
edgeStream:
enable: true
Patches
This bug has been fixed in Kubeedge 1.11.1, 1.10.2, 1.9.4. Users should update to these versions to resolve the issue.
Workarounds
Disable cloudStream module in the config file cloudcore.yaml and disable edgeStream module in the config file edgecore.yaml, restart process cloudcore and edgecore after modification.
References
NA
Credits
Thanks David Korczynski and Adam Korczynski of ADA Logics for responsibly disclosing this issue in accordance with the kubeedge security policy during a security audit sponsored by CNCF and facilitated by OSTIF.
For more information
If you have any questions or comments about this advisory:
- Open an issue in KubeEdge repo
- To make a vulnerability report, email your vulnerability to the private [email protected] list with the security details and the details expected for KubeEdge bug reports.
- Record
GHSA-wrcr-x4qj-j543- CVSS 3.1
- 4.4 Medium
CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-400, CWE-770
- Updated
- 2026-11-02
NVD
4.4
KubeEdge is an open source system for extending native containerized application orchestration capabilities to hosts at Edge. Prior to versions 1.11.1, 1.10.2, and 1.9.4, the Cloud Stream server and the Edge Stream server reads the entire message into memory without imposing a limit on the size of this message. An attacker can exploit this by sending a large message to exhaust memory and cause a DoS. The Cloud Stream server and the Edge Stream server are under DoS attack in this case. The consequence of the exhaustion is that the CloudCore and EdgeCore will be in a denial of service. Only an authenticated user can cause this issue. It will be affected only when users enable cloudStream module in the config file cloudcore.yaml and enable edgeStream module in the config file edgecore.yaml. This bug has been fixed in Kubeedge 1.11.1, 1.10.2, and 1.9.4. As a workaround, disable cloudStream module in the config file cloudcore.yaml and disable edgeStream module in the config file edgecore.yaml.
- Record
CVE-2022-31079- CVSS 3.1
- 4.4 Medium
CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H - CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H - CVSS 2.0
- 3.5 Low
AV:N/AC:M/Au:S/C:N/I:N/A:P - Weakness
- CWE-400, CWE-770
- Updated
- 2026-11-02
OSV
4.4
KubeEdge Cloud Stream and Edge Stream DoS from large stream message
KubeEdge is an open source system for extending native containerized application orchestration capabilities to hosts at Edge. Prior to versions 1.11.1, 1.10.2, and 1.9.4, the Cloud Stream server and the Edge Stream server reads the entire message into memory without imposing a limit on the size of this message. An attacker can exploit this by sending a large message to exhaust memory and cause a DoS. The Cloud Stream server and the Edge Stream server are under DoS attack in this case. The consequence of the exhaustion is that the CloudCore and EdgeCore will be in a denial of service. Only an authenticated user can cause this issue. It will be affected only when users enable cloudStream module in the config file cloudcore.yaml and enable edgeStream module in the config file edgecore.yaml. This bug has been fixed in Kubeedge 1.11.1, 1.10.2, and 1.9.4. As a workaround, disable cloudStream module in the config file cloudcore.yaml and disable edgeStream module in the config file edgecore.yaml.
- Record
CVE-2022-31079- CVSS 3.1
- 4.4 Medium
CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-400
- Updated
- 2026-11-02
OSVGHSA-wrcr-x4qj-j543
4.4
KubeEdge Cloud Stream and Edge Stream DoS from large stream message
Impact
The Cloud Stream server and the Edge Stream server reads the entire message into memory without imposing a limit on the size of this message. An attacker can exploit this by sending a large message to exhaust memory and cause a DoS. The Cloud Stream server and the Edge Stream server are under DoS attack in this case. The consequence of the exhaustion is that the CloudCore and EdgeCore will be in a denial of service. Only an authenticated user can cause this issue. It will be affected only when users enable cloudStream module in the config file cloudcore.yaml and enable edgeStream module in the config file edgecore.yaml as below. cloudcore.yaml:
modules:
...
cloudStream:
enable: true
edgecore.yaml:
modules:
...
edgeStream:
enable: true
Patches
This bug has been fixed in Kubeedge 1.11.1, 1.10.2, 1.9.4. Users should update to these versions to resolve the issue.
Workarounds
Disable cloudStream module in the config file cloudcore.yaml and disable edgeStream module in the config file edgecore.yaml, restart process cloudcore and edgecore after modification.
References
NA
Credits
Thanks David Korczynski and Adam Korczynski of ADA Logics for responsibly disclosing this issue in accordance with the kubeedge security policy during a security audit sponsored by CNCF and facilitated by OSTIF.
For more information
If you have any questions or comments about this advisory:
- Open an issue in KubeEdge repo
- To make a vulnerability report, email your vulnerability to the private [email protected] list with the security details and the details expected for KubeEdge bug reports.
- Record
GHSA-wrcr-x4qj-j543- CVSS 3.1
- 4.4 Medium
CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-400, CWE-770
- Updated
- 2026-11-02
OSVGO-2022-0511 No score
KubeEdge Cloud Stream and Edge Stream DoS from large stream message in github.com/kubeedge/kubeedge
KubeEdge Cloud Stream and Edge Stream DoS from large stream message in github.com/kubeedge/kubeedge
- Record
GO-2022-0511- Updated
- 2026-11-02
Affected products
Affected packages
| Package | Affected | Fixed |
|---|---|---|
github.com/kubeedge/kubeedgeGo |
1.11.0 up to 1.11.1 | 1.11.1 |
github.com/kubeedge/kubeedgeGo |
1.10.0 up to 1.10.2 | 1.10.2 |
github.com/kubeedge/kubeedgeGo |
before 1.9.4 | 1.9.4 |
github.com/kubeedge/kubeedgeGo |
before 1.9.4, 1.10.0 up to 1.10.2, 1.11.0 up to 1.11.1 | 1.9.41.10.21.11.1 |
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD, OSV |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2022-31079 is a medium vulnerability (CVSS 4.4) in Kubeedge, published July 11, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.70%, the 53rd percentile. Fixed in github.com/kubeedge/kubeedge 1.11.1.