Every CVE Search/ Get API key

CVE-2022-34377

Dell PowerEdge BIOS contains an Improper SMM communication buffer verification vulnerability. A...

1.9 Low

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
High
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
Low

Exploit likelihood

0.17%Down 0.9 points since Feb 11, 2023
90%50%10%1%

What each source reports

CVE List Score used 1.9

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Record
CVE-2022-34377
CVSS 3.1
1.9 LowCVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:L
Weakness
CWE-119
Updated
2026-11-02
EUVDEUVD-2022-37332 1.9

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Record
EUVD-2022-37332
CVSS 3.1
1.9 LowCVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:L
Updated
2026-11-02
GitHub AdvisoriesGHSA-88vj-f7qv-vm8f 6.7

Dell PowerEdge BIOS contains an Improper SMM communication buffer verification vulnerability. A...

Dell PowerEdge BIOS contains an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Record
GHSA-88vj-f7qv-vm8f
CVSS 3.1
6.7 MediumCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-119
Updated
2026-11-02
NVD 1.9

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Record
CVE-2022-34377
CVSS 3.1
1.9 LowCVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:L
CVSS 3.1
6.7 MediumCVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-119
Updated
2026-11-02

Affected products

Show 69 moreShow less

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2022-34377 is a low vulnerability (CVSS 1.9) in Dell C4130 Firmware, published February 10, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.17%, the 5th percentile. No source names a fixed version.

References

MoveEnter Open