Every CVE Search/ Get API key

CVE-2022-3575

Frauscher Sensortechnik Diagnostic System FDS102 for FAdC R2 and FAdCi R2 configuration upload vulnerability

9.8 Critical

Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.86%Unchanged since Nov 3, 2022
90%50%10%1%

What each source reports

CVE List Score used 9.8

Frauscher Sensortechnik Diagnostic System FDS102 for FAdC R2 and FAdCi R2 configuration upload vulnerability

Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device.

Record
CVE-2022-3575
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-434
Updated
2026-11-02
EUVDEUVD-2022-42939 9.8

Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device.

Record
EUVD-2022-42939
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-rhx5-m86r-5gj6 9.8

Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to...

Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device.

Record
GHSA-rhx5-m86r-5gj6
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-434
Updated
2026-11-02
NVD 9.8

Frauscher Sensortechnik GmbH FDS102 for FAdC R2 and FAdCi R2 v2.8.0 to v2.9.1 are vulnerable to malicious code upload without authentication by using the configuration upload function. This could lead to a complete compromise of the FDS102 device.

Record
CVE-2022-3575
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-434
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2022-3575 is a critical vulnerability (CVSS 9.8) in Frauscher Sensortechnik Diagnostic System Fds102, published November 2, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.86%, the 58th percentile. No source names a fixed version.

References

MoveEnter Open