CVE-2022-37130
In D-Link DIR-816 A2_v1.10CNB04.img a command injection vulnerability occurs in /goform/Diagnosis...
In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability
- Record
CVE-2022-37130- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-78
- Updated
- 2026-11-02
CVE List No score
In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability
- Record
CVE-2022-37130- Updated
- 2026-11-02
EUVDEUVD-2022-39783 No score
In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability
- Record
EUVD-2022-39783- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-v9f5-5rq4-cwc6
9.8
In D-Link DIR-816 A2_v1.10CNB04.img a command injection vulnerability occurs in /goform/Diagnosis...
In D-Link DIR-816 A2_v1.10CNB04.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability
- Record
GHSA-v9f5-5rq4-cwc6- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-77
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2022-37130 is a critical vulnerability (CVSS 9.8) in Dlink Dir-816 Firmware, published August 31, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 26.9%, the 98th percentile. No source names a fixed version.