CVE-2022-40282
The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection....
The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection. This allows an authenticated attacker to pass commands to the shell of the system because the dir parameter of the FsCreateDir Ajax function is not sufficiently sanitized. The vendor's ID is BSECV-2022-21.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
8.8
The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection. This allows an authenticated attacker to pass commands to the shell of the system because the dir parameter of the FsCreateDir Ajax function is not sufficiently sanitized. The vendor's ID is BSECV-2022-21.
- Record
CVE-2022-40282- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-77
- Updated
- 2026-11-02
CVE List
8.8
The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection. This allows an authenticated attacker to pass commands to the shell of the system because the dir parameter of the FsCreateDir Ajax function is not sufficiently sanitized. The vendor's ID is BSECV-2022-21.
- Record
CVE-2022-40282- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-77
- Updated
- 2026-11-02
EUVDEUVD-2022-43579
8.8
The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection. This allows an authenticated attacker to pass commands to the shell of the system because the dir parameter of the FsCreateDir Ajax function is not sufficiently sanitized. The vendor's ID is BSECV-2022-21.
- Record
EUVD-2022-43579- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-355f-6hm6-3cc4 No score
The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection....
The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection. This allows an authenticated attacker to pass commands to the shell of the system because the dir parameter of the FsCreateDir Ajax function is not sufficiently sanitized. The vendor's ID is BSECV-2022-21.
- Record
GHSA-355f-6hm6-3cc4- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2022-40282 is a high vulnerability (CVSS 8.8) in Belden Hirschmann Bat-c2 Firmware, published November 25, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 4.17%, the 90th percentile. No source names a fixed version.