A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An...

4.2 Medium

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
High
User interaction
Required

What an attacker can affect

Confidentiality
High
Integrity
None
Availability
None

Exploit likelihood

0.14%Up 0.1 points since Dec 13, 2023
90%50%10%1%

What each source reports

CVE List Score used 4.2

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.

Record
CVE-2022-46141
CVSS 3.1
4.2 MediumCVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C
Weakness
CWE-316
Updated
2026-11-02
EUVDEUVD-2022-48979 4.2

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.

Record
EUVD-2022-48979
CVSS 3.1
4.2 MediumCVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C
Updated
2026-11-03
GitHub AdvisoriesGHSA-2wph-4xpg-r884 4.2

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An...

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.

Record
GHSA-2wph-4xpg-r884
CVSS 3.1
4.2 MediumCVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N
Weakness
CWE-312, CWE-316
Updated
2026-11-02
NVD 4.2

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.

Record
CVE-2022-46141
CVSS 3.1
4.2 MediumCVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N
CVSS 3.1
5.5 MediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-316, CWE-312
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2022-46141 is a medium vulnerability (CVSS 4.2) in Siemens Simatic Step 7 (tia Portal), published December 12, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.14%, the 3rd percentile. No source names a fixed version.

References

MoveEnter Open