CVE-2023-0808
Deye/Revolt/Bosswerk Inverter Access Point Setting hard-coded password
A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability.
Attack profile
How easy it is to exploit
- Attack vector
- Physical
- Complexity
- High
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- Low
- Integrity
- Low
- Availability
- Low
Exploit likelihood
What each source reports
CVE List Score used 3.9
Deye/Revolt/Bosswerk Inverter Access Point Setting hard-coded password
A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability.
- Record
CVE-2023-0808- CVSS 3.1
- 3.9 Low
CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L - CVSS 3.0
- 3.9 Low
CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L - CVSS 2.0
- 3.7
AV:L/AC:H/Au:N/C:P/I:P/A:P - Weakness
- CWE-259
- Updated
- 2026-11-02
EUVDEUVD-2023-12813 3.9
A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability.
- Record
EUVD-2023-12813- CVSS 3.1
- 3.9 Low
CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-j998-c4rh-83vq 6.8
A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471....
A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability.
- Record
GHSA-j998-c4rh-83vq- CVSS 3.1
- 6.8 Medium
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-259, CWE-798
- Updated
- 2026-11-02
NVD 3.9
A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability.
- Record
CVE-2023-0808- CVSS 3.1
- 3.9 Low
CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L - CVSS 3.1
- 6.8 Medium
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 3.7 Low
AV:L/AC:H/Au:N/C:P/I:P/A:P - Weakness
- CWE-259, CWE-798
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, published | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2023-0808 is a low vulnerability (CVSS 3.9) in Bosswerk Inverter, published February 13, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.23%, the 14th percentile. No source names a fixed version.