CVE-2023-1751
CVE-2023-1751
The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the bearer token in the Authorization header belongs to the device attempting to associate. This could allow any authorized user to receive alarm information and signals meant for other devices which leak a deviceId.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
7.5
CVE-2023-1751
The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the bearer token in the Authorization header belongs to the device attempting to associate. This could allow any authorized user to receive alarm information and signals meant for other devices which leak a deviceId.
- Record
CVE-2023-1751- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Updated
- 2026-11-02
EUVDEUVD-2023-23972
7.5
The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the bearer token in the Authorization header belongs to the device attempting to associate. This could allow any authorized user to receive alarm information and signals meant for other devices which leak a deviceId.
- Record
EUVD-2023-23972- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-8j4q-8455-qxw3
5.3
The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if...
The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the bearer token in the Authorization header belongs to the device attempting to associate. This could allow any authorized user to receive alarm information and signals meant for other devices which leak a deviceId.
- Record
GHSA-8j4q-8455-qxw3- CVSS 3.1
- 5.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N - Updated
- 2026-11-02
NVD
7.5
The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the bearer token in the Authorization header belongs to the device attempting to associate. This could allow any authorized user to receive alarm information and signals meant for other devices which leak a deviceId.
- Record
CVE-2023-1751- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - CVSS 3.1
- 5.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N - Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, published | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2023-1751 is a high vulnerability (CVSS 7.5) in Getnexx Nxal-100 Firmware, published April 4, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.59%, the 48th percentile. No source names a fixed version.