Every CVE Search/ Get API key

CVE-2023-22441

Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which...

8.6 High

Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
Low
Availability
High

Exploit likelihood

0.98%Up 0.9 points since May 10, 2023
90%50%10%1%

What each source reports

NVD Score used 8.6

Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier

Record
CVE-2023-22441
CVSS 3.1
8.6 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Weakness
CWE-306
Updated
2026-11-02
CVE List 8.6

Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier

Record
CVE-2023-22441
CVSS 3.1
8.6 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Weakness
CWE-306
Updated
2026-11-02
EUVDEUVD-2023-26603 8.6

Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier

Record
EUVD-2023-26603
CVSS 3.1
8.6 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-qwcg-gr98-8m32 8.6

Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which...

Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier

Record
GHSA-qwcg-gr98-8m32
CVSS 3.1
8.6 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Weakness
CWE-306
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2023-22441 is a high vulnerability (CVSS 8.6) in Seiko-sol Skybridge Basic Mb-a130 Firmware, published May 10, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.98%, the 62nd percentile. No source names a fixed version.