CVE-2023-26058
An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to a Performance...
An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to a Performance Manager page. Input validation and a proper XML parser configuration are missing. For an external attacker, it is very difficult to exploit this, because a few dynamically created parameters such as Jsession-id, a CSRF token, and an Nxsrf token would be needed. The attack can realistically only be performed by an internal user.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
6.5
An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to a Performance Manager page. Input validation and a proper XML parser configuration are missing. For an external attacker, it is very difficult to exploit this, because a few dynamically created parameters such as Jsession-id, a CSRF token, and an Nxsrf token would be needed. The attack can realistically only be performed by an internal user.
- Record
CVE-2023-26058- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AC:L/AV:N/A:N/C:H/I:N/PR:L/S:U/UI:N - Weakness
- CWE-611
- Updated
- 2026-11-02
EUVDEUVD-2023-29932
6.5
An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to a Performance Manager page. Input validation and a proper XML parser configuration are missing. For an external attacker, it is very difficult to exploit this, because a few dynamically created parameters such as Jsession-id, a CSRF token, and an Nxsrf token would be needed. The attack can realistically only be performed by an internal user.
- Record
EUVD-2023-29932- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AC:L/AV:N/A:N/C:H/I:N/PR:L/S:U/UI:N - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-7946-5rp5-f5v2
6.5
An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to a Performance...
An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to a Performance Manager page. Input validation and a proper XML parser configuration are missing. For an external attacker, it is very difficult to exploit this, because a few dynamically created parameters such as Jsession-id, a CSRF token, and an Nxsrf token would be needed. The attack can realistically only be performed by an internal user.
- Record
GHSA-7946-5rp5-f5v2- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-611
- Updated
- 2026-11-02
NVD
6.5
An XXE issue was discovered in Nokia NetAct before 22 FP2211 via an XML document to a Performance Manager page. Input validation and a proper XML parser configuration are missing. For an external attacker, it is very difficult to exploit this, because a few dynamically created parameters such as Jsession-id, a CSRF token, and an Nxsrf token would be needed. The attack can realistically only be performed by an internal user.
- Record
CVE-2023-26058- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-611
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2023-26058 is a medium vulnerability (CVSS 6.5) in Nokia Netact, published April 25, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.49%, the 42nd percentile. No source names a fixed version.