Every CVE Search/ Get API key

CVE-2023-34347

​Delta Electronics InfraSuite Device Master Deserialization of Untrusted Data

9.8 Critical

​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.95%Up 0.9 points since Jul 11, 2023
90%50%10%1%

What each source reports

CVE List Score used 9.8

​Delta Electronics InfraSuite Device Master Deserialization of Untrusted Data

​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.

Record
CVE-2023-34347
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-502
Updated
2026-11-02
EUVDEUVD-2023-38427 9.8

​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.

Record
EUVD-2023-38427
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-6q78-28qr-rqfx 9.8

?Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that...

?Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.

Record
GHSA-6q78-28qr-rqfx
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-502
Updated
2026-11-02
NVD 9.8

​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.

Record
CVE-2023-34347
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-502
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2023-34347 is a critical vulnerability (CVSS 9.8) in Delta Electronics Infrasuite Device Master, published July 10, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.95%, the 61st percentile. No source names a fixed version.

References

MoveEnter Open