CVE-2023-49147
An issue was discovered in PDF24 Creator 11.14.0. The configuration of the msi installer file was...
An issue was discovered in PDF24 Creator 11.14.0. The configuration of the msi installer file was found to produce a visible cmd.exe window when using the repair function of msiexec.exe. This allows an unprivileged local attacker to use a chain of actions (e.g., an oplock on faxPrnInst.log) to open a SYSTEM cmd.exe.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
7.8
An issue was discovered in PDF24 Creator 11.14.0. The configuration of the msi installer file was found to produce a visible cmd.exe window when using the repair function of msiexec.exe. This allows an unprivileged local attacker to use a chain of actions (e.g., an oplock on faxPrnInst.log) to open a SYSTEM cmd.exe.
- Record
CVE-2023-49147- CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
CVE List No score
An issue was discovered in PDF24 Creator 11.14.0. The configuration of the msi installer file was found to produce a visible cmd.exe window when using the repair function of msiexec.exe. This allows an unprivileged local attacker to use a chain of actions (e.g., an oplock on faxPrnInst.log) to open a SYSTEM cmd.exe.
- Record
CVE-2023-49147- Updated
- 2026-11-02
EUVDEUVD-2023-53152 No score
An issue was discovered in PDF24 Creator 11.14.0. The configuration of the msi installer file was found to produce a visible cmd.exe window when using the repair function of msiexec.exe. This allows an unprivileged local attacker to use a chain of actions (e.g., an oplock on faxPrnInst.log) to open a SYSTEM cmd.exe.
- Record
EUVD-2023-53152- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-cj6f-97f2-wp7j
7.8
An issue was discovered in PDF24 Creator 11.14.0. The configuration of the msi installer file was...
An issue was discovered in PDF24 Creator 11.14.0. The configuration of the msi installer file was found to produce a visible cmd.exe window when using the repair function of msiexec.exe. This allows an unprivileged local attacker to use a chain of actions (e.g., an oplock on faxPrnInst.log) to open a SYSTEM cmd.exe.
- Record
GHSA-cj6f-97f2-wp7j- CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2023-49147 is a high vulnerability (CVSS 7.8) in Pdf24 Creator, published December 19, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.49%, the 42nd percentile. No source names a fixed version.
References
seclists.org/fulldisclosure/2023/Dec/18
packetstormsecurity.com/files/176206/PDF24-Creator-11.15.1-Local-Privilege-Escalation.html
sec-consult.com/vulnerability-lab/advisory/local-privilege-escalation-via-msi-installer-in-pdf24-creator-geek-software-gmbh
nvd.nist.gov/vuln/detail/CVE-2023-49147
github.com/advisories/GHSA-cj6f-97f2-wp7j