CVE-2023-6320
Command injection in the com.webos.service.connectionmanager/tv/setVlanStaticAddress endpoint
A command injection vulnerability exists in the com.webos.service.connectionmanager/tv/setVlanStaticAddress endpoint on webOS versions 5 and 6. A series of specially crafted requests can lead to command execution as the dbus user. An attacker can make authenticated requests to trigger this vulnerability.
Full versions and TV models affected:
-
webOS 5.5.0 - 04.50.51 running on OLED55CXPUA
-
webOS 6.3.3-442 (kisscurl-kinglake) - 03.36.50 running on OLED48C1PUB
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- High
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
9.1
Command injection in the com.webos.service.connectionmanager/tv/setVlanStaticAddress endpoint
A command injection vulnerability exists in the com.webos.service.connectionmanager/tv/setVlanStaticAddress endpoint on webOS versions 5 and 6. A series of specially crafted requests can lead to command execution as the dbus user. An attacker can make authenticated requests to trigger this vulnerability.
Full versions and TV models affected:
-
webOS 5.5.0 - 04.50.51 running on OLED55CXPUA
-
webOS 6.3.3-442 (kisscurl-kinglake) - 03.36.50 running on OLED48C1PUB
- Record
CVE-2023-6320- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H - Weakness
- CWE-78
- Updated
- 2026-11-02
EUVDEUVD-2023-58562
9.1
A command injection vulnerability exists in the com.webos.service.connectionmanager/tv/setVlanStaticAddress endpoint on webOS versions 5 and 6. A series of specially crafted requests can lead to command execution as the dbus user. An attacker can make authenticated requests to trigger this vulnerability.
Full versions and TV models affected:
-
webOS 5.5.0 - 04.50.51 running on OLED55CXPUA
-
webOS 6.3.3-442 (kisscurl-kinglake) - 03.36.50 running on OLED48C1PUB
- Record
EUVD-2023-58562- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-wm52-4cc3-xxgg
9.1
A command injection vulnerability exists in the com.webos.service.connectionmanager/tv...
A command injection vulnerability exists in the com.webos.service.connectionmanager/tv/setVlanStaticAddress endpoint on webOS versions 5 and 6. A series of specially crafted requests can lead to command execution as the dbus user. An attacker can make authenticated requests to trigger this vulnerability.
Full versions and TV models affected:
-
webOS 5.5.0 - 04.50.51 running on OLED55CXPUA
-
webOS 6.3.3-442 (kisscurl-kinglake) - 03.36.50 running on OLED48C1PUB
- Record
GHSA-wm52-4cc3-xxgg- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H - Weakness
- CWE-78
- Updated
- 2026-11-02
NVD
9.1
A command injection vulnerability exists in the com.webos.service.connectionmanager/tv/setVlanStaticAddress endpoint on webOS versions 5 and 6. A series of specially crafted requests can lead to command execution as the dbus user. An attacker can make authenticated requests to trigger this vulnerability.
Full versions and TV models affected:
-
webOS 5.5.0 - 04.50.51 running on OLED55CXPUA
-
webOS 6.3.3-442 (kisscurl-kinglake) - 03.36.50 running on OLED48C1PUB
- Record
CVE-2023-6320- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H - CVSS 3.1
- 7.2 High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-78
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, published | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2023-6320 is a critical vulnerability (CVSS 9.1) in Lg Webos, published April 9, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 3.95%, the 90th percentile. No source names a fixed version.