iniNet Solutions SpiderControl SCADA PC HMI Editor Path Traversal

8.6 High

iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or writing to startup items, resulting in remote control.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
Low
User interaction
Passive

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.50%Up 0.5 points since Oct 25, 2024
90%50%10%1%

What each source reports

CVE List Score used 8.6

iniNet Solutions SpiderControl SCADA PC HMI Editor Path Traversal

iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or writing to startup items, resulting in remote control.

Record
CVE-2024-10313
CVSS 4.0
8.6 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVSS 3.1
8.0 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-22
Updated
2026-11-02
EUVDEUVD-2024-33033 8.6

iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or writing to startup items, resulting in remote control.

Record
EUVD-2024-33033
CVSS 4.0
8.6 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Updated
2026-11-03
GitHub AdvisoriesGHSA-hqr5-gxvv-5ff4 8.6

iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the...

iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or writing to startup items, resulting in remote control.

Record
GHSA-hqr5-gxvv-5ff4
CVSS 4.0
8.6 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
8.0 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-22
Updated
2026-11-02
NVD 8.6

iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or writing to startup items, resulting in remote control.

Record
CVE-2024-10313
CVSS 4.0
8.6 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
8.0 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-22
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2024-10313 is a high vulnerability (CVSS 8.6) in Ininet Solutions Spidercontrol Scada Pc Hmi Editor, published October 24, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.50%, the 43rd percentile. No source names a fixed version.

References

MoveEnter Open