Every CVE Search/ Get API key

CVE-2024-10576

Unauthorized factory reset of Infinix devices

9.4 Critical

Infinix devices contain a pre-loaded "com.transsion.agingfunction" application, that exposes an unsecured broadcast receiver. An attacker can communicate with the receiver and force the device to perform a factory reset without any Android system permissions. 

After multiple attempts to contact the vendor we did not receive any answer. We suppose this issue affects all Infinix Mobile devices.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.17%Up 0.1 points since Dec 5, 2024
90%50%10%1%

What each source reports

CVE List Score used 9.4

Unauthorized factory reset of Infinix devices

Infinix devices contain a pre-loaded "com.transsion.agingfunction" application, that exposes an unsecured broadcast receiver. An attacker can communicate with the receiver and force the device to perform a factory reset without any Android system permissions. 

After multiple attempts to contact the vendor we did not receive any answer. We suppose this issue affects all Infinix Mobile devices.

Record
CVE-2024-10576
CVSS 4.0
9.4 CriticalCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/S:N/R:I/V:D/U:Amber
Weakness
CWE-925
Updated
2026-11-02
EUVDEUVD-2024-33513 9.4

Infinix devices contain a pre-loaded "com.transsion.agingfunction" application, that exposes an unsecured broadcast receiver. An attacker can communicate with the receiver and force the device to perform a factory reset without any Android system permissions. 

After multiple attempts to contact the vendor we did not receive any answer. We suppose this issue affects all Infinix Mobile devices.

Record
EUVD-2024-33513
CVSS 4.0
9.4 CriticalCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/S:N/R:I/V:D/U:Amber
Updated
2026-11-03
GitHub AdvisoriesGHSA-phgf-8v5r-r8p3 9.4

Infinix devices contain a pre-loaded "com.transsion.agingfunction" application, that exposes an...

Infinix devices contain a pre-loaded "com.transsion.agingfunction" application, that exposes an unsecured broadcast receiver. An attacker can communicate with the receiver and force the device to perform a factory reset without any Android system permissions. 

After multiple attempts to contact the vendor we did not receive any answer. We suppose this issue affects all Infinix Mobile devices.

Record
GHSA-phgf-8v5r-r8p3
CVSS 4.0
9.4 CriticalCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:X/R:I/V:D/RE:X/U:Amber
Weakness
CWE-925
Updated
2026-11-02
NVD 9.4

Infinix devices contain a pre-loaded "com.transsion.agingfunction" application, that exposes an unsecured broadcast receiver. An attacker can communicate with the receiver and force the device to perform a factory reset without any Android system permissions. 

After multiple attempts to contact the vendor we did not receive any answer. We suppose this issue affects all Infinix Mobile devices.

Record
CVE-2024-10576
CVSS 4.0
9.4 CriticalCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:X/R:I/V:D/RE:X/U:Amber
Weakness
CWE-925
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2024-10576 is a critical vulnerability (CVSS 9.4) in Infinix Mobile Com.transsion.agingfunction, published December 4, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.17%, the 5th percentile. No source names a fixed version.

References