CVE-2024-25139
In TP-Link Omada er605 1.0.1 through (v2.6) 2.2.3, a cloud-brd binary is susceptible to an...
In TP-Link Omada er605 1.0.1 through (v2.6) 2.2.3, a cloud-brd binary is susceptible to an integer overflow that leads to a heap-based buffer overflow. After heap shaping, an attacker can achieve code execution in the context of the cloud-brd binary that runs at the root level. This is fixed in ER605(UN)_v2_2.2.4 Build 020240119.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
10.0
In TP-Link Omada er605 1.0.1 through (v2.6) 2.2.3, a cloud-brd binary is susceptible to an integer overflow that leads to a heap-based buffer overflow. After heap shaping, an attacker can achieve code execution in the context of the cloud-brd binary that runs at the root level. This is fixed in ER605(UN)_v2_2.2.4 Build 020240119.
- Record
CVE-2024-25139- CVSS 3.1
- 10.0 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H - Weakness
- CWE-120
- Updated
- 2026-11-02
EUVDEUVD-2024-22487
10.0
In TP-Link Omada er605 1.0.1 through (v2.6) 2.2.3, a cloud-brd binary is susceptible to an integer overflow that leads to a heap-based buffer overflow. After heap shaping, an attacker can achieve code execution in the context of the cloud-brd binary that runs at the root level. This is fixed in ER605(UN)_v2_2.2.4 Build 020240119.
- Record
EUVD-2024-22487- CVSS 3.1
- 10.0 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-xhjf-xjwg-rm34
10.0
In TP-Link Omada er605 1.0.1 through (v2.6) 2.2.3, a cloud-brd binary is susceptible to an...
In TP-Link Omada er605 1.0.1 through (v2.6) 2.2.3, a cloud-brd binary is susceptible to an integer overflow that leads to a heap-based buffer overflow. After heap shaping, an attacker can achieve code execution in the context of the cloud-brd binary that runs at the root level. This is fixed in ER605(UN)_v2_2.2.4 Build 020240119.
- Record
GHSA-xhjf-xjwg-rm34- CVSS 3.1
- 10.0 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H - Weakness
- CWE-120
- Updated
- 2026-11-02
NVD
10.0
In TP-Link Omada er605 1.0.1 through (v2.6) 2.2.3, a cloud-brd binary is susceptible to an integer overflow that leads to a heap-based buffer overflow. After heap shaping, an attacker can achieve code execution in the context of the cloud-brd binary that runs at the root level. This is fixed in ER605(UN)_v2_2.2.4 Build 020240119.
- Record
CVE-2024-25139- CVSS 3.1
- 10.0 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H - Weakness
- CWE-120
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2024-25139 is a critical vulnerability (CVSS 10.0) in Tp-link Omada Er605, published March 14, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.88%, the 59th percentile. No source names a fixed version.