Every CVE Search/ Get API key

CVE-2024-2981

Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

8.8 High

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

1.77%Up 1.7 points since Mar 28, 2024
90%50%10%1%

What each source reports

CVE List Score used 8.8

Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Record
CVE-2024-2981
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 3.0
8.8 HighCVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
9.0 AV:N/AC:L/Au:S/C:C/I:C/A:C
Weakness
CWE-121
Updated
2026-11-02
EUVDEUVD-2024-27921 8.8

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Record
EUVD-2024-27921
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-252r-cvww-g3vf 8.8

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408)....

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Record
GHSA-252r-cvww-g3vf
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-121, CWE-787
Updated
2026-11-02
NVD 8.8

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Record
CVE-2024-2981
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
9.0 HighAV:N/AC:L/Au:S/C:C/I:C/A:C
Weakness
CWE-121, CWE-787
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2024-2981 is a high vulnerability (CVSS 8.8) in Tenda Fh1202, published March 27, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.77%, the 78th percentile. No source names a fixed version.

References

MoveEnter Open