CVE-2024-31815
In TOTOLINK EX200 V4.0.3c.7314_B20191204, an attacker can obtain the configuration file without...
In TOTOLINK EX200 V4.0.3c.7314_B20191204, an attacker can obtain the configuration file without authorization through /cgi-bin/ExportSettings.sh
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
9.1
In TOTOLINK EX200 V4.0.3c.7314_B20191204, an attacker can obtain the configuration file without authorization through /cgi-bin/ExportSettings.sh
- Record
CVE-2024-31815- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Weakness
- CWE-639
- Updated
- 2026-11-02
EUVDEUVD-2024-29688
9.1
In TOTOLINK EX200 V4.0.3c.7314_B20191204, an attacker can obtain the configuration file without authorization through /cgi-bin/ExportSettings.sh
- Record
EUVD-2024-29688- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-gpf5-g943-4fxx
9.1
In TOTOLINK EX200 V4.0.3c.7314_B20191204, an attacker can obtain the configuration file without...
In TOTOLINK EX200 V4.0.3c.7314_B20191204, an attacker can obtain the configuration file without authorization through /cgi-bin/ExportSettings.sh
- Record
GHSA-gpf5-g943-4fxx- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Weakness
- CWE-284, CWE-639
- Updated
- 2026-11-02
NVD
9.1
In TOTOLINK EX200 V4.0.3c.7314_B20191204, an attacker can obtain the configuration file without authorization through /cgi-bin/ExportSettings.sh
- Record
CVE-2024-31815- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Weakness
- CWE-639
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2024-31815 is a critical vulnerability (CVSS 9.1) in Totolink Ex200 Firmware, published April 8, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.58%, the 48th percentile. No source names a fixed version.