Every CVE Search/ Get API key

CVE-2024-35522

Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an...

8.4 High

Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

1.87%Up 1.8 points since Oct 12, 2024
90%50%10%1%

What each source reports

CVE List Score used 8.4

Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.

Record
CVE-2024-35522
CVSS 3.1
8.4 HighCVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N
Weakness
CWE-77
Updated
2026-11-02
EUVDEUVD-2024-35351 8.4

Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.

Record
EUVD-2024-35351
CVSS 3.1
8.4 HighCVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N
Updated
2026-11-02
GitHub AdvisoriesGHSA-r58v-99w5-7j3x 8.4

Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an...

Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.

Record
GHSA-r58v-99w5-7j3x
CVSS 3.1
8.4 HighCVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-77
Updated
2026-11-02
NVD 8.4

Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.

Record
CVE-2024-35522
CVSS 3.1
8.4 HighCVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-77
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2024-35522 is a high vulnerability (CVSS 8.4) in Netgear Ex3700 Ac750, published October 11, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.87%, the 79th percentile. No source names a fixed version.

References

MoveEnter Open