CVE-2024-37570
On Mitel 6869i 4.5.0.41 devices, the Manual Firmware Update (upgrade.html) page does not perform...
On Mitel 6869i 4.5.0.41 devices, the Manual Firmware Update (upgrade.html) page does not perform sanitization on the username and path parameters (sent by an authenticated user) before appending flags to the busybox ftpget command. This leads to $() command execution.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
8.8
On Mitel 6869i 4.5.0.41 devices, the Manual Firmware Update (upgrade.html) page does not perform sanitization on the username and path parameters (sent by an authenticated user) before appending flags to the busybox ftpget command. This leads to $() command execution.
- Record
CVE-2024-37570- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-77
- Updated
- 2026-11-02
CVE List
8.8
On Mitel 6869i 4.5.0.41 devices, the Manual Firmware Update (upgrade.html) page does not perform sanitization on the username and path parameters (sent by an authenticated user) before appending flags to the busybox ftpget command. This leads to $() command execution.
- Record
CVE-2024-37570- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-77
- Updated
- 2026-11-02
EUVDEUVD-2024-36766
8.8
On Mitel 6869i 4.5.0.41 devices, the Manual Firmware Update (upgrade.html) page does not perform sanitization on the username and path parameters (sent by an authenticated user) before appending flags to the busybox ftpget command. This leads to $() command execution.
- Record
EUVD-2024-36766- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-683h-wmfw-2p2m
8.8
On Mitel 6869i 4.5.0.41 devices, the Manual Firmware Update (upgrade.html) page does not perform...
On Mitel 6869i 4.5.0.41 devices, the Manual Firmware Update (upgrade.html) page does not perform sanitization on the username and path parameters (sent by an authenticated user) before appending flags to the busybox ftpget command. This leads to $() command execution.
- Record
GHSA-683h-wmfw-2p2m- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-75, CWE-77
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2024-37570 is a high vulnerability (CVSS 8.8) in Mitel 6869i Sip Firmware, published June 9, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.06%, the 64th percentile. No source names a fixed version.