Every CVE Search/ Get API key

CVE-2024-6242

Rockwell Automation Chassis Restrictions Bypass Vulnerability in Select Logix Devices

7.3 High

A vulnerability exists in Rockwell Automation affected products that allows a threat actor to bypass the Trusted® Slot feature in a ControlLogix® controller. If exploited on any affected module in a 1756 chassis, a threat actor could potentially execute CIP commands that modify user projects and/or device configuration on a Logix controller in the chassis.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
High
Availability
High

Exploit likelihood

11.1%Up 11.1 points since Aug 6, 2024
90%50%10%1%

What each source reports

CVE List Score used 7.3

Rockwell Automation Chassis Restrictions Bypass Vulnerability in Select Logix Devices

A vulnerability exists in Rockwell Automation affected products that allows a threat actor to bypass the Trusted® Slot feature in a ControlLogix® controller. If exploited on any affected module in a 1756 chassis, a threat actor could potentially execute CIP commands that modify user projects and/or device configuration on a Logix controller in the chassis.

Record
CVE-2024-6242
CVSS 4.0
7.3 HighCVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H
Weakness
CWE-420
Updated
2026-11-02
EUVDEUVD-2024-47370 7.3

A vulnerability exists in Rockwell Automation affected products that allows a threat actor to bypass the Trusted® Slot feature in a ControlLogix® controller. If exploited on any affected module in a 1756 chassis, a threat actor could potentially execute CIP commands that modify user projects and/or device configuration on a Logix controller in the chassis.

Record
EUVD-2024-47370
CVSS 4.0
7.3 HighCVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-6h2q-3m5q-wv4c 7.3

A vulnerability exists in Rockwell Automation affected products that allows a threat actor to...

A vulnerability exists in Rockwell Automation affected products that allows a threat actor to bypass the Trusted® Slot feature in a ControlLogix® controller. If exploited on any affected module in a 1756 chassis, a threat actor could potentially execute CIP commands that modify user projects and/or device configuration on a Logix controller in the chassis.

Record
GHSA-6h2q-3m5q-wv4c
CVSS 4.0
7.3 HighCVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weakness
CWE-420
Updated
2026-11-02
NVD 7.3

A vulnerability exists in Rockwell Automation affected products that allows a threat actor to bypass the Trusted® Slot feature in a ControlLogix® controller. If exploited on any affected module in a 1756 chassis, a threat actor could potentially execute CIP commands that modify user projects and/or device configuration on a Logix controller in the chassis.

Record
CVE-2024-6242
CVSS 4.0
7.3 HighCVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weakness
CWE-420
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2024-6242 is a high vulnerability (CVSS 7.3) in Rockwell Automation 1756-en2f, published August 1, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 11.1%, the 95th percentile. No source names a fixed version.

References

MoveEnter Open