CVE-2024-7408
Information Disclosure Vulnerability in Airveda Air Quality Monitor
This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.
Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- None
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
8.6
Information Disclosure Vulnerability in Airveda Air Quality Monitor
This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.
Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.
- Record
CVE-2024-7408- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H - Weakness
- CWE-319
- Updated
- 2026-11-02
EUVDEUVD-2024-48334
8.6
This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.
Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.
- Record
EUVD-2024-48334- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-3wvg-3mmq-332j
8.6
This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of...
This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.
Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.
- Record
GHSA-3wvg-3mmq-332j- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-319
- Updated
- 2026-11-02
NVD
8.6
This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.
Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.
- Record
CVE-2024-7408- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-319
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, published | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2024-7408 is a high vulnerability (CVSS 8.6) in Airveda Air Quality Monitor Pm2.5 Pm10, published August 9, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.26%, the 17th percentile. No source names a fixed version.