Every CVE Search/ Get API key

CVE-2024-7408

Information Disclosure Vulnerability in Airveda Air Quality Monitor

8.6 High

This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.

Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
None
Availability
High

Exploit likelihood

0.26%Up 0.2 points since Aug 13, 2024
90%50%10%1%

What each source reports

CVE List Score used 8.6

Information Disclosure Vulnerability in Airveda Air Quality Monitor

This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.

Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.

Record
CVE-2024-7408
CVSS 4.0
8.6 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H
Weakness
CWE-319
Updated
2026-11-02
EUVDEUVD-2024-48334 8.6

This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.

Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.

Record
EUVD-2024-48334
CVSS 4.0
8.6 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-3wvg-3mmq-332j 8.6

This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of...

This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.

Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.

Record
GHSA-3wvg-3mmq-332j
CVSS 4.0
8.6 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
6.5 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-319
Updated
2026-11-02
NVD 8.6

This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.

Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.

Record
CVE-2024-7408
CVSS 4.0
8.6 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
6.5 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-319
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2024-7408 is a high vulnerability (CVSS 8.6) in Airveda Air Quality Monitor Pm2.5 Pm10, published August 9, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.26%, the 17th percentile. No source names a fixed version.

References

MoveEnter Open