Every CVE Search/ Get API key

CVE-2024-7731

SECOM Dr.ID Access control system - SQL injection

9.8 Critical

Dr.ID Access Control System from SECOM does not properly validate a specific page parameter, allowing unauthenticated remote attackers to inject SQL commands to read, modify, and delete database contents.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.83%Up 0.7 points since Aug 15, 2024
90%50%10%1%

What each source reports

CVE List Score used 9.8

SECOM Dr.ID Access control system - SQL injection

Dr.ID Access Control System from SECOM does not properly validate a specific page parameter, allowing unauthenticated remote attackers to inject SQL commands to read, modify, and delete database contents.

Record
CVE-2024-7731
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-89
Updated
2026-11-02
EUVDEUVD-2024-48608 9.8

Dr.ID Access Control System from SECOM does not properly validate a specific page parameter, allowing unauthenticated remote attackers to inject SQL commands to read, modify, and delete database contents.

Record
EUVD-2024-48608
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-24q9-34wm-r8c7 9.8

Dr.ID Access Control System from SECOM does not properly validate a specific page parameter,...

Dr.ID Access Control System from SECOM does not properly validate a specific page parameter, allowing unauthenticated remote attackers to inject SQL commands to read, modify, and delete database contents.

Record
GHSA-24q9-34wm-r8c7
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-89
Updated
2026-11-02
NVD 9.8

Dr.ID Access Control System from SECOM does not properly validate a specific page parameter, allowing unauthenticated remote attackers to inject SQL commands to read, modify, and delete database contents.

Record
CVE-2024-7731
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-89
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2024-7731 is a critical vulnerability (CVSS 9.8) in Secom Dr.id Access Control System, published August 14, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.83%, the 57th percentile. No source names a fixed version.

References

MoveEnter Open