Every CVE Search/ Get API key

CVE-2025-10461

Global file reads caused by improper URL checks in webserver

5.3 Medium

Global file reads caused by improper URL checks in webserver in Softing Industrial Automation GmbH smartLinks on docker (filesystem modules) allows file access.

This issue affects

smartLink SW-HT: through 1.42

smartLink SW-PN: through 1.03.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
Low
Availability
Low

Exploit likelihood

0.39%Up 0.3 points since Mar 17, 2026
90%50%10%1%

What each source reports

CVE List Score used 5.3

Global file reads caused by improper URL checks in webserver

Global file reads caused by improper URL checks in webserver in Softing Industrial Automation GmbH smartLinks on docker (filesystem modules) allows file access.

This issue affects

smartLink SW-HT: through 1.42

smartLink SW-PN: through 1.03.

Record
CVE-2025-10461
CVSS 4.0
5.3 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/AU:Y/R:A/RE:L/U:Green
Weakness
CWE-20
Updated
2026-11-02
EUVDEUVD-2025-208725 5.3

Global file reads caused by improper URL checks in webserver in Softing Industrial Automation GmbH smartLinks on docker (filesystem modules) allows file access.

This issue affects

smartLink SW-HT: through 1.42

smartLink SW-PN: through 1.03.

Record
EUVD-2025-208725
CVSS 4.0
5.3 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/AU:Y/R:A/RE:L/U:Green
Updated
2026-11-02
GitHub AdvisoriesGHSA-xg46-rrcq-9x53 5.3

Global file reads caused by improper URL checks in webserver in Softing Industrial Automation...

Global file reads caused by improper URL checks in webserver in Softing Industrial Automation GmbH smartLinks on docker (filesystem modules) allows file access.

This issue affects

smartLink SW-HT: through 1.42

smartLink SW-PN: through 1.03.

Record
GHSA-xg46-rrcq-9x53
CVSS 4.0
5.3 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:A/V:X/RE:L/U:Green
Weakness
CWE-20
Updated
2026-11-02
NVD 5.3

Global file reads caused by improper URL checks in webserver in Softing Industrial Automation GmbH smartLinks on docker (filesystem modules) allows file access.

This issue affects

smartLink SW-HT: through 1.42

smartLink SW-PN: through 1.03.

Record
CVE-2025-10461
CVSS 4.0
5.3 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:A/V:X/RE:L/U:Green
Weakness
CWE-20
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-10461 is a medium vulnerability (CVSS 5.3) in Softing Smartlink Sw-ht, published March 16, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.39%, the 33rd percentile. No source names a fixed version.

References

MoveEnter Open