CVE-2025-10504
Heap Memory Corruption Vulnerability
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- High
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
6.9
Heap Memory Corruption Vulnerability
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
- Record
CVE-2025-10504- CVSS 4.0
- 6.9 Medium
CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L - CVSS 3.1
- 6.1 Medium
CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H - Weakness
- CWE-122
- Updated
- 2026-11-02
EUVDEUVD-2025-31494
6.9
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
- Record
EUVD-2025-31494- CVSS 4.0
- 6.9 Medium
CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-j5wc-gp95-6rjq
5.7
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC...
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
- Record
GHSA-j5wc-gp95-6rjq- CVSS 4.0
- 5.7 Medium
CVSS:4.0/AV:L/AC:H/AT:P/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 5.7 Medium
CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H - Weakness
- CWE-122
- Updated
- 2026-11-02
NVD
6.9
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
- Record
CVE-2025-10504- CVSS 4.0
- 6.9 Medium
CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:N/R:A/V:D/RE:L/U:X - CVSS 3.1
- 6.1 Medium
CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H - Weakness
- CWE-122
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2025-10504 is a medium vulnerability (CVSS 6.9) in Abb Terra Ac Wallbox, published September 29, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.21%, the 10th percentile. No source names a fixed version.