Stack Memory Corruption Vulnerability

6.9 Medium

Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
High
Availability
High

Exploit likelihood

0.21%Up 0.2 points since Nov 29, 2025
90%50%10%1%

What each source reports

CVE List Score used 6.9

Stack Memory Corruption Vulnerability

Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.

Record
CVE-2025-12143
CVSS 4.0
6.9 MediumCVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L
CVSS 3.1
6.1 MediumCVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
Weakness
CWE-121
Updated
2026-11-02
EUVDEUVD-2025-199870 6.9

Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.

Record
EUVD-2025-199870
CVSS 4.0
6.9 MediumCVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L
Updated
2026-11-02
GitHub AdvisoriesGHSA-xqrg-6p99-hc76 6.9

Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC...

Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.

Record
GHSA-xqrg-6p99-hc76
CVSS 4.0
6.9 MediumCVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:N/R:A/V:D/RE:L/U:X
CVSS 3.1
6.1 MediumCVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
Weakness
CWE-121
Updated
2026-11-02
NVD 6.9

Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.

Record
CVE-2025-12143
CVSS 4.0
6.9 MediumCVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:N/R:A/V:D/RE:L/U:X
CVSS 3.1
6.1 MediumCVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
Weakness
CWE-121
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-12143 is a medium vulnerability (CVSS 6.9) in Abb Terra Ac Wallbox, published November 28, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.21%, the 10th percentile. No source names a fixed version.