CVE-2025-24916
Improper Access Control leads to Local Priviledge Escalation
When installing Tenable Network Monitor to a non-default location on a Windows host, Tenable Network Monitor versions prior to 6.5.1 did not enforce secure permissions for sub-directories. This could allow for local privilege escalation if users had not secured the directories in the non-default installation location.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- High
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
7.0
Improper Access Control leads to Local Priviledge Escalation
When installing Tenable Network Monitor to a non-default location on a Windows host, Tenable Network Monitor versions prior to 6.5.1 did not enforce secure permissions for sub-directories. This could allow for local privilege escalation if users had not secured the directories in the non-default installation location.
- Record
CVE-2025-24916- CVSS 3.1
- 7.0 High
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-284
- Updated
- 2026-11-02
EUVDEUVD-2025-16336
7.0
When installing Tenable Network Monitor to a non-default location on a Windows host, Tenable Network Monitor versions prior to 6.5.1 did not enforce secure permissions for sub-directories. This could allow for local privilege escalation if users had not secured the directories in the non-default installation location.
- Record
EUVD-2025-16336- CVSS 3.1
- 7.0 High
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-9wpx-f5qr-7rcr
7.0
When installing Tenable Network Monitor to a non-default location on a Windows host, Tenable...
When installing Tenable Network Monitor to a non-default location on a Windows host, Tenable Network Monitor versions prior to 6.5.1 did not enforce secure permissions for sub-directories. This could allow for local privilege escalation if users had not secured the directories in the non-default installation location.
- Record
GHSA-9wpx-f5qr-7rcr- CVSS 3.1
- 7.0 High
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-284
- Updated
- 2026-11-02
NVD
7.0
When installing Tenable Network Monitor to a non-default location on a Windows host, Tenable Network Monitor versions prior to 6.5.1 did not enforce secure permissions for sub-directories. This could allow for local privilege escalation if users had not secured the directories in the non-default installation location.
- Record
CVE-2025-24916- CVSS 3.1
- 7.0 High
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H - CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-284
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2025-24916 is a high vulnerability (CVSS 7.0) in Tenable Network Monitor, published May 23, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.16%, the 4th percentile. No source names a fixed version.