Every CVE Search/ Get API key

CVE-2025-27253

An improper input validation in GE Vernova UR IED family devices from version 7.0 up to 8.60...

6.1 Medium

A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
None
Availability
Low

Exploit likelihood

0.23%Up 0.2 points since Mar 11, 2025
90%50%10%1%

What each source reports

CVE List Score used 6.1

A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network.

Record
CVE-2025-27253
CVSS 3.1
6.1 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L
Weakness
CWE-15
Updated
2026-11-02
EUVDEUVD-2025-7757 6.1

A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network.

Record
EUVD-2025-7757
CVSS 3.1
6.1 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L
Updated
2026-11-02
GitHub AdvisoriesGHSA-j5vp-q6vg-25mf 6.1

An improper input validation in GE Vernova UR IED family devices from version 7.0 up to 8.60...

An improper input validation in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that enstablishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network

Record
GHSA-j5vp-q6vg-25mf
CVSS 3.1
6.1 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L
Weakness
CWE-15, CWE-20
Updated
2026-11-02
NVD 6.1

A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network.

Record
CVE-2025-27253
CVSS 3.1
6.1 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L
Weakness
CWE-15
Updated
2026-11-02

Affected products

Show 7 moreShow less

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-27253 is a medium vulnerability (CVSS 6.1) in Ge Vernova B30 Multilin, published March 10, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.23%, the 14th percentile. No source names a fixed version.

References

MoveEnter Open