CVE-2025-27769
A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4...
A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.
Attack profile
How easy it is to exploit
- Attack vector
- Physical
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- Low
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
2.4
A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.
- Record
CVE-2025-27769- CVSS 4.0
- 2.4 Low
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N - CVSS 3.1
- 2.6 Low
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N - Weakness
- CWE-923
- Updated
- 2026-11-02
EUVDEUVD-2025-208479
2.4
A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.
- Record
EUVD-2025-208479- CVSS 4.0
- 2.4 Low
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-vc7r-jrpg-m6j5
2.4
A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4...
A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.
- Record
GHSA-vc7r-jrpg-m6j5- CVSS 4.0
- 2.4 Low
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 2.6 Low
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N - Weakness
- CWE-923
- Updated
- 2026-11-02
NVD
2.4
A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.
- Record
CVE-2025-27769- CVSS 4.0
- 2.4 Low
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 2.6 Low
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N - Weakness
- CWE-923
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short