CVE-2025-29121
A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality...
A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
7.5
A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.
- Record
CVE-2025-29121- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-121
- Updated
- 2026-11-02
EUVDEUVD-2025-7173
7.5
A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.
- Record
EUVD-2025-7173- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-v6jq-9h5f-2qcm
7.5
A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality...
A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.
- Record
GHSA-v6jq-9h5f-2qcm- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-121
- Updated
- 2026-11-02
NVD
7.5
A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.
- Record
CVE-2025-29121- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-121
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2025-29121 is a high vulnerability (CVSS 7.5) in Tenda Ac6 Firmware, published March 20, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.48%, the 41st percentile. No source names a fixed version.