Every CVE Search/ Get API key

CVE-2025-29121

A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality...

7.5 High

A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

0.48%Up 0.5 points since Mar 21, 2025
90%50%10%1%

What each source reports

CVE List Score used 7.5

A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.

Record
CVE-2025-29121
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-121
Updated
2026-11-02
EUVDEUVD-2025-7173 7.5

A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.

Record
EUVD-2025-7173
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-v6jq-9h5f-2qcm 7.5

A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality...

A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.

Record
GHSA-v6jq-9h5f-2qcm
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-121
Updated
2026-11-02
NVD 7.5

A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.

Record
CVE-2025-29121
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-121
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-29121 is a high vulnerability (CVSS 7.5) in Tenda Ac6 Firmware, published March 20, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.48%, the 41st percentile. No source names a fixed version.

References

MoveEnter Open