Every CVE Search/ Get API key

CVE-2025-30661

Junos OS: Low-privileged user can cause script to run as root, leading to privilege escalation

8.5 High

An Incorrect Permission Assignment for Critical Resource vulnerability in line card script processing of Juniper Networks Junos OS allows a local, low-privileged user to install scripts to be executed as root, leading to privilege escalation.

A local user with access to the local file system can copy a script to the router in a way that will be executed as root, as the system boots. Execution of the script as root can lead to privilege escalation, potentially providing the adversary complete control of the system.

This issue only affects specific line cards, such as the MPC10, MPC11, LC4800, LC9600, MX304-LMIC16, SRX4700, and EX9200-15C.

This issue affects Junos OS: * from 23.2 before 23.2R2-S4, 

  • from 23.4 before 23.4R2-S5, 
  • from 24.2 before 24.2R2-S1, 
  • from 24.4 before 24.4R1-S3, 24.4R2.

This issue does not affect versions prior to 23.1R2.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
None
User interaction
Passive

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.20%Up 0.2 points since Jul 12, 2025
90%50%10%1%

What each source reports

CVE List Score used 8.5

Junos OS: Low-privileged user can cause script to run as root, leading to privilege escalation

An Incorrect Permission Assignment for Critical Resource vulnerability in line card script processing of Juniper Networks Junos OS allows a local, low-privileged user to install scripts to be executed as root, leading to privilege escalation.

A local user with access to the local file system can copy a script to the router in a way that will be executed as root, as the system boots. Execution of the script as root can lead to privilege escalation, potentially providing the adversary complete control of the system.

This issue only affects specific line cards, such as the MPC10, MPC11, LC4800, LC9600, MX304-LMIC16, SRX4700, and EX9200-15C.

This issue affects Junos OS: * from 23.2 before 23.2R2-S4, 

  • from 23.4 before 23.4R2-S5, 
  • from 24.2 before 24.2R2-S1, 
  • from 24.4 before 24.4R1-S3, 24.4R2.

This issue does not affect versions prior to 23.1R2.

Record
CVE-2025-30661
CVSS 4.0
8.5 HighCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/AU:N/R:U/RE:M/U:Amber
CVSS 3.1
7.3 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-732
Updated
2026-11-02
EUVDEUVD-2025-21165 8.5

An Incorrect Permission Assignment for Critical Resource vulnerability in line card script processing of Juniper Networks Junos OS allows a local, low-privileged user to install scripts to be executed as root, leading to privilege escalation.

A local user with access to the local file system can copy a script to the router in a way that will be executed as root, as the system boots. Execution of the script as root can lead to privilege escalation, potentially providing the adversary complete control of the system.

This issue only affects specific line cards, such as the MPC10, MPC11, LC4800, LC9600, MX304-LMIC16, SRX4700, and EX9200-15C.

This issue affects Junos OS: * from 23.2 before 23.2R2-S4, 

  • from 23.4 before 23.4R2-S5, 
  • from 24.2 before 24.2R2-S1, 
  • from 24.4 before 24.4R1-S3, 24.4R2.

This issue does not affect versions prior to 23.1R2.

Record
EUVD-2025-21165
CVSS 4.0
8.5 HighCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/AU:N/R:U/RE:M/U:Amber
Updated
2026-11-02
NVD 8.5

An Incorrect Permission Assignment for Critical Resource vulnerability in line card script processing of Juniper Networks Junos OS allows a local, low-privileged user to install scripts to be executed as root, leading to privilege escalation.

A local user with access to the local file system can copy a script to the router in a way that will be executed as root, as the system boots. Execution of the script as root can lead to privilege escalation, potentially providing the adversary complete control of the system.

This issue only affects specific line cards, such as the MPC10, MPC11, LC4800, LC9600, MX304-LMIC16, SRX4700, and EX9200-15C.

This issue affects Junos OS: * from 23.2 before 23.2R2-S4, 

  • from 23.4 before 23.4R2-S5, 
  • from 24.2 before 24.2R2-S1, 
  • from 24.4 before 24.4R1-S3, 24.4R2.

This issue does not affect versions prior to 23.1R2.

Record
CVE-2025-30661
CVSS 4.0
8.5 HighCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:N/R:U/V:X/RE:M/U:Amber
CVSS 3.1
7.3 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-732
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-30661 is a high vulnerability (CVSS 8.5) in Juniper Junos, published July 11, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.20%, the 9th percentile. No source names a fixed version.

References

MoveEnter Open